BMOV
- 127 -
Program example
(1) Program to transmit the current values of T33 to 48 to D908 to 923.
Coding
No. of
steps
Com-
mand
Device
10 LD M90
11 BMOV T33 D908 H10
BMOV
D908T33 H10
M90
10
16
T31
Before execution
(Transmission source)
0100
0010
0100
0999
1005
0115
0000
T32
T33
T34
T35
T48
T49
D906
0000
03FF
0100
0999
1005
0115
1000
D907
D908
D909
D910
D923
D924
16 data items
After execution
(Transmission destinasion)
Block transmission with BMOV command