9. Exclusive Commands
- 242 -
9.6.4 Chopping interface
(1) PLC→NC
Device No. Abbreviation Signal name
Y1E8 CHPS Chopping
(2) NC→PLC
In chopping start, intervals during chopping and chopping mode are output.
Device No. Abbreviation Signal name
X260 CHOP In chopping start
X261 CHP1 Basic position→upper dead point
X262 CHP2 Upper dead point→bottom dead point
X263 CHP3 Bottom dead point→upper dead point
X264 CHP4 Upper dead point→basic position
X265 CHPMD In chopping mode
(3) Chopping override (PLC→NC)
Set within the range of 0% to 100% by 1% increments.
Device No. Abbreviation Signal name
R135 CHPOV Chopping override