9. Exclusive Commands
- 231 -
(2) Status
The search state is indicated.
The status is set by the controller and is used by PLC for completion check, etc.
F82103
Search processing
Search completion
Search error completion
External
search No
option
<Error cause>
Data specification error
The status is cleared by the controller when the search start instruction execution condition is off.
(3) Program number
Specify the program number to be searched in binary form in the range of 1 to 99999999 (eight
digits).
Specify 0 to search for the sequence number of the current program selected.
If a number other than 0~99999999 is specified, a data specification error will occur.
(4) Sequence number
Specify the sequence number to be searched in binary form in the range of 1 to 99999 (five
digits).
Specify 0 to search for the head of the specified program number.
If a number other than 0~99999 is specified, a data specification error will occur.
(5) Block number
Specify the block number to be searched in binary form in the range of 0 to 99 (two digits).
If a number other than 0~99 is specified, a data specified error will occur.
Program No. Sequence No. Search
Specified Specified Memory or tape is searched for the specified sequence
number of the specified program.
Specified Not specified (=0) Memory or tape is searched for the top of the specified
program.
Not specified (=0) Specified Memory or tape is searched for the specified sequence
number of the current program selected.
Not specified (=0) Not specified (=0) Error (no specification)
(6) System specification
This is not used. "0" is set.