Section 4: Getting started
June 2014
Section 4: Getting started
Starting, stopping and resetting the logger
To start data logging, change the logging interval (P590) from 0 to the interval required.
Logging is now activated.
Changing the logging interval from 0 to a logging interval in minutes will clear all data logged
(i.e. clear the 7000 event-memory plus the 60 midnight totals).
Changing the log interval from a non-zero interval (e.g. 15 minutes) to a new non-zero interval
(e.g. 5 minutes) will clear the 7000 event-memory).
To stop data logging, change the logging interval (P590) back to 0. Note, when the data logging
interval is re-set, all logged data will be cleared from the logging memory.
Figure 4-23. Navigating to the LOGGING Menu
Figure 4-24. Menu map for LOGGING screens
MAIN MENU
Run App?
MONITOR
SETUP
SELECT INSTRUMENT
Tx1: ****
Controller: ****
SETUP
DISPLAY
OUTPUT
LOGGING
LOGGING
Log Interval
Fast Log
Logging Wizard
Logging Wizard
ESC=Quit =Start
Note: The SELECT INSTRUMENT menu does not
appear unless a HART transmitter is connected.
x3
LOGGING
Log Interval
Fast Log
Logging Wizard
LOGGING
Data Overwrite
Low Mem Alarm
Fast Log
Log Interval P590
0 min
Esc=Quit =Edit
Fast Log P591
0.0000 m
Esc=Quit =Edit
Data Overwrite P592
On
Esc=Quit =Edit
Low Mem Alarm P593
0 %
Esc=Quit =Edit