Emerson MCU900 Video Game Controller User Manual


 
55
Reference Manual
IP2030/RM, Rev AA
Section 4: Getting started
June 2014
Section 4: Getting started
Figure 4-19. Examples of popular non-linear (non-uniform) vessel applications
Note
The non-linear profile (NLP) is plotted automatically when editing P113 / P123
manually or when using the Application (App) Wizard, except for the Conical NLP.
Menu: SETUP / [CONTROLLER /] APPLICATION / App Wizard
P115 / P125 is plotted with a simple cone if P113 / P123 is set to Conical manually.
P113/P123 = Spherical
P114/P124 = (1.0 / Diameter of tank)
P115/P125 = Plotted non-linear profile of tank
P116/P126 = Full volume of ideal spherical tank
P113/P123 = Horiz Cyl Flat
(Horizontal Cylinder, Flat Ends, Slope Ignored)
P114/P124 = (1.0 / Diameter of tank)
P115/P125 = Plotted non-linear profile of tank
P116/P126 = Full volume of ideal cylindrical tank
P113/P123 = Conical
P114/P124 = (1.0 / Maximum level)
P115/P125 = Plotted non-linear profile of tank
P116/P126 = Full volume of ideal conical tank