Agilent Technologies 90B Video Gaming Accessories User Manual


 
84
causing the output voltage to rise to some value higher than the maximum voltage rating of the supply. With
some loads this could result in serious damage. To protect loads from accidental opening of the remote
programming leads, a zener diode should be placed directly across the power supply programming terminals.
This zener diode is selected to have a breakdown voltage equal to the maximum power supply voltage that can
be tolerated by the load. Thus, if the programming terminals open, the programming current will cause the
zener diode to break down, and the output voltage will be limited to the zener diode voltage. Such a zener diode
must be capable of dissipating a power equal to the product of its breakdown voltage times the programming
current I
P
.
CONSTANT VOLTAGE REMOTE PROGRAMMING WITH VOLTAGE CONTROL
Instead of controlling a power supply by means of a programming resistance, it is possible to control the output
of any remotely programmable supply with an input voltage. Thus, the power supply becomes a low frequency
dc amplifier. Remote Programming Speed (later in this section) stresses the bandwidth and speed of response of
this configuration, whereas these paragraphs deal only with the method of control.
Two distinct methods can be employed to voltage program: unity and variable voltage gain.
Programming with Unity Voltage Gain
This method, shown in Figure 57, requires that the external voltage be exactly equal to the desired output
voltage.
Figure 57. Voltage Programming with Unity Voltage Gain
The current required from the voltage source E
P
is at most several milliamps. Of course, this voltage source
must be free of ripple and noise and any other undesired imperfections, since within the regulator bandwidth the
power supply will attempt to reproduce on its output terminals the programming voltage input on a one-for-one