Agilent Technologies 90B Video Gaming Accessories User Manual


 
14
PROGRAMMING SPEED
The maximum time required for the output voltage or current to change from an initial value to within a
tolerance band of the newly programmed value following the onset of a step change in the programming input
signal. Because the programming speed depends on the loading of the supply and on whether the output is being
programmed to a higher or lower value, programming speed is usually specified at no load and full load and in
both the up and down directions.
PROGRAMMING SPEED WAVEFORMS
REMOTE PROGRAMMING (REMOTE CONTROL)
Control of the regulated output voltage or current of a power supply by means of a remotely varied resistance or
voltage. The illustrations below show examples of constant voltage remote programming. CC applications are
similar.
REMOTE PROGRAMMING USING RESISTANCE CONTROL
REMOTE PROGRAMMING USING VOLTAGE CONTROL