3Com WX1200 3CRWX120695A Video Game Controller User Manual


 
set radius 583
MSS encrypts the display form of the string in display config and
display aaa output.
retransmit number — Number of transmission attempts the WX
switch makes before declaring an unresponsive RADIUS server
unavailable. You can specify from 1 to 100 retries.
timeout seconds — Number of seconds the WX switch waits for the
RADIUS server to respond before retransmitting. You can specify from
1 to 65,535.
Defaults — Global RADIUS parameters have the following default
values:
deadtime — 0 (zero) minutes (The WX switch does not designate
unresponsive RADIUS servers as unavailable.)
encrypted-key—No key
key — No key
retransmit — 3 (the total number of attempts, including the first
attempt)
timeout — 5 seconds
Access — Enabled.
History —Introduced in MSS Version 3.0. The encrypted-key option
was added in Version 4.2.
Usage — You can specify only one parameter per command line.
Examples — The following commands sets the dead time to 5 minutes,
the RADIUS key to goody, the number of retransmissions to 1, and the
timeout to 21 seconds on all RADIUS servers connected to the WX
switch:
WX1200# set radius deadtime 5
success: change accepted.
WX1200# set radius key goody
success: change accepted.
WX1200# set radius retransmit 1
success: change accepted.
WX1200# set radius timeout 21
success: change accepted.