8. Special I/O Functions
8.5 Analog setting function
Function
The value of the analog setting adjuster is converted into a digital value (0 to 1000) and
stored in the SW register. 2 adjusters are provided. (V0 and V1)
The SW register data can be used as timer presets or any parameters for function
instructions.
Related registers
Function Register Remarks
Adjuster V0 SW30 Data range: 0 to 1000
Adjuster V1 SW31
Operation
V0 V1
SW30 (0 to 1000) SW31 (0 to 1000)
Sample program
The above example is a simple flicker circuit of Y020. In this example, the ON/OFF
interval of Y020 can be controlled by the adjuster V0.
Decrease
Increase
Decrease
Increase