Toshiba 6F3B0250 Video Gaming Accessories User Manual


 
6F3B0250
212
T1/T1S User’s Manual
7. Instructions
FUN 112
U
<
Unsigned less than
Expression
Input
-
[
A
U
<
B
]
-
Output
Function
When the input is ON, the data of
A
and the data of
B
are compared, and if
A
is less than
B
, the output
is turned ON.
Execution condition
Input Operation Output
OFF No execution OFF
ON Execution
A
<
B
ON
A
³
B
OFF
Operand
Name Device Re
g
ister Constant Index
X Y R S T. C. XW YW RW SW T C D I J K
A
Compared
data
ÖÖÖÖÖÖÖÖÖÖ Ö Ö
B
Reference data
ÖÖÖÖÖÖÖÖÖÖ Ö Ö
Example
When R00C is ON, the data of D0125 is compared with the data of D0040, and if the data of
D0125 is less than the data of D0040, R020 is turned ON.
If the data of D0125 is 43000 and that of D0040 is 45000, the comparison result is true.
Consequently, R020 is turned ON.
D0125 43000
<
D0040 45000 R020 is ON
If the data of D0125 is 50000 and that of D0040 is 50000, the comparison result is false.
Consequently, R020 is turned OFF.
D0125 50000
³
D0040 50000 R020 is OFF
Note
·
This instruction deals with the data as unsigned integer (0 to 65535).
T1S only