6F3B0250
Basic Hardware and Function
211
7. Instructions
FUN 111
U
<>
Unsigned not equal
Expression
Input
-
[
A
U
<>
B
]
-
Output
Function
When the input is ON, the data of
A
and the data of
B
are compared, and if
A
is not equal to
B
, the
output is turned ON.
Execution condition
Input Operation Output
OFF No execution OFF
ON Execution
A
¹
B
ON
A
=
B
OFF
Operand
Name Device Re
g
ister Constant Index
X Y R S T. C. XW YW RW SW T C D I J K
A
Compared
data
ÖÖÖÖÖÖÖÖÖÖ Ö Ö
B
Reference data
ÖÖÖÖÖÖÖÖÖÖ Ö Ö
Example
When R00C is ON, the data of D0125 is compared with the constant data 0, and if the data of
D0125 is not 0, R020 is turned ON.
If the data of D0125 is 41000, the comparison result is true. Consequently, R020 is turned ON.
D0125 41000
¹
Constant 0 R020 is ON
If the data of D0125 is 0, the comparison result is false. Consequently, R020 is turned OFF.
D0125 0
=
Constant 0 R020 is OFF
Note
·
This instruction deals with the data as unsigned integer (0 to 65535).
T1S only
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net