6F3B0250
Basic Hardware and Function
155
7. Instructions
FUN 019 DMOV Double-word data transfer
Expression
Input
-
[
A+1
×
A
MOV
B+1
×
B
]
-
Output
Function
When the input is ON, the double-word (32-bit) data of
A+1
×
A
is stored in double-word register
B+1
×
B
.
The data range is -2147483648 to 2147483647.
Execution condition
Input Operation Output
OFF No execution OFF
ON Execution ON
Operand
Name Device Re
g
ister Constant Index
X Y R S T. C. XW YW RW SW T C D I J K
A
Source
ÖÖÖÖÖÖÖÖÖÖ Ö Ö
B
Destination
ÖÖÖÖÖÖÖÖÖ Ö
Example
When R011 is ON, a double-word data of D0101
×
D0100 is stored in RW17
×
RW16 and the output
is turned ON. If D0101
×
D0100 is 1234567, the data 1234567 is stored in RW17
×
RW16.