Agilent Technologies 66319b Video Games User Manual


 
Quick Reference - 1
15
Front Panel Menus - At a Glance
ADDRESS 7
Sets the GPIB Address
LANG SCPI
Selects language (SCPI)
REMOTE FP OFF
Enables or disables Agilent 14575A remote front panel (ON | OFF)
ROM: A.00.00
Displays the firmware revision of the instrument
SN: US12345678
Displays the serial number of the instrument
*RCL 0
Recalls the instrument state
*SAV 0
Saves the present instrument state
ERROR 0
Displays the number of errors in the SCPI error queue
2
5.000V 0.104A
Toggles the display between output 1 and output 2 (output 2 shown)
1
12.000V
1
0.204A
Measures the output voltage and current (output 1 shown)
1
12.500V MAX
Measures the peak output voltage
1
1.000V MIN
Measures the minimum output voltage
1
12.330V HIGH
Measures the high level of a voltage pulse waveform
1
0.080V LOW
Measures the low level of a voltage pulse waveform
1
12.000V RMS
Measures the rms voltage
1
0.350A MAX
Measures the peak output current
1
0.050A MIN
Measures the minimum output current
1
0.400A HIGH
Measures the high level of a current pulse waveform
1
0.012A LOW
Measures the low level of a current pulse waveform
1
0.210A RMS
Measures the rms current
1
12.000V DC:DVM
Measures the dc voltage on the DVM input
1
1
12.000V RMS:DVM
Measures the rms voltage on the DVM input
1
1
VOLT 12.000
2
VOLT 2.000
Sets the voltage of output 1 on all models
Sets the voltage of output 2
2
1
CURR 2.000
2
CURR 1.000
Sets the current limit of output 1 on all models
Sets the current limit of output 2
2
1
RES 1.000
Sets the resistance of output 1 on all models
OVERCURRENT
Protection status (example shows overcurrent tripped)
*RST
Places the dc source in the factory-default state
COUPLING ALL
Couples or decouples output 1 and output 2 (NONE or ALL)
1
COMP LLOCAL
Sets the output compensation (HREMOTE, LREMOTE, HLOCAL or LLOCAL)
PON:STATE RST
Select the power-on state command (RST or RCL0)
PROT:DLY 0.08
Sets the output protection delay in seconds
RI LATCHING
Sets the remote inhibit mode (LATCHING, LIVE, or OFF)
DFI OFF
Sets the discrete fault indicator state (ON or OFF)
DFI:SOUR OFF
Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)
PORT RIDFI
Sets the output port functions (RIDFI, DIGIO, or TRIGGER)
DIGIO 7
Sets and reads the I/O port value (0 through 7)
SENSE:PROT OFF
Enables or disables the open sense lead detect circuit (ON or OFF)
1
REL:MODE DD
Sets the relay mode for Option 521 units (DD, HD, DH, or HH) (output 1 shown)
VOLT:PROT 10.000
Sets the programmable voltage limit for output 1
PROT:STAT ON
Enables or disables overvoltage protection for output 1 (ON or OFF)
CURR:RANG MAX
Sets the current range (3A, 1A, 0.02A, or AUTO)
CURR:DET ACDC
Sets the current measurement detector (ACDC or DC)
TINT 46.8
Sets the time interval for a front panel measurement in seconds
POINT 2048
Sets the buffer size for a front panel measurement
CAL ON
Accesses calibration menu (See Appendix B)
Use and to select parameters (table shows factory defaults). Use to exit any menu.
1
Only valid for Agilent Model 66319B/D
2
Only valid for Agilent Model 66321D/66319D
Address
$
$$
$
$
$$
$
Recall
Save Shift
Error
$
$$
$
$
$$
$
Shift
Meter
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
Channel
$
$$
$
Shift
Voltage
Protect
Current
Output
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
$
$$
$
OV Shift
$
$$
$
$
$$
$
Shift
Shift
Res
Input
$
$$
$
Cal Shift
Meter #
##
# &
&&
&
$
$$
$
$
$$
$