Agilent Technologies 66319b Video Games User Manual


 
8 – Language Dictionary
102
MEASure:CURRent? [MAX | MIN | <NR3>]
FETCh:CURRent?
These queries return the dc output current. You can specifying an optional range parameter for the
MEASure:CURent? query. This lets you use a different current range for a single measurement instance
without having to change the current range using the SENSe:CURRent:RANGe command. Afer the
measurement completes, the range returns to the value specified by SENSe:CURRent:RANGe.
Query Syntax
MEASure[:SCALar]:CURRent[:DC]? [MAX | MIN | <NR3>]
FETCh[:SCALar]:CURRent[:DC]?
Parameters
None
Examples
MEAS:CURR? FETC:CURR:DC?
Returned Parameters
<NR3>
Related Commands
MEAS:VOLT? SENS:CURR:RANG
MEASure:CURRent2?
Agilent 66319B/D only
This query measures the output current at the auxiliary output. Output 2 measurements are calculated
from a total of 2048 readings taken at a 15.6 microsecond sampling rate. These parameters are fixed.
Query Syntax
MEASure[:SCALar]:CURRent2[:DC]?
Parameters
None
Examples
MEAS:CURR2? FETC:CURR2:DC?
Returned Parameters
<NR3>
Related Commands
MEAS:VOLT2?
MEASure:CURRent:ACDC?
FETCh:CURRent:ACDC?
These queries return the ac+dc rms output current.
Query Syntax
MEASure[:SCALar]:CURRent:ACDC?
FETCh[:SCALar]:CURRent:ACDC?
Parameters
None
Examples
MEAS:CURR:ACDC? FETC:CURR:ACDC?
Returned Parameters
<NR3>
Related Commands
MEAS:VOLT:ACDC?