Dell R900 Video Game Console User Manual


 
About Your System 37
Memory address line failure
at address, read value
expecting value
Memory double word logic
failure at address, read
value expecting value
Memory odd/even logic failure
at address, read value
expecting value
Memory write/read failure at
address, read value expecting
value
Faulty or improperly seated DIMMs or
defective system board
Memory tests terminated by
keystroke
POST memory test terminated by
pressing the <spacebar>
No boot device available Faulty diskette, diskette/tape drive
subsystem, hard-disk drive, hard-disk
drive subsystem, or no boot disk in drive
A
No boot sector on hard-disk
drive
Incorrect configuration settings in System
Setup program, or no operating system on
hard-disk drive
No timer tick interrupt Defective system board
Not a boot diskette No operating system on diskette
PCI BIOS failed to installed PCI device BIOS (Option ROM)
checksum failure is detected during
shadowing
Plug & Play Configuration
error
Plug & Play Configuration error is
detected during PCI device scan
Read fault
Requested sector not found
Faulty diskette, diskette/tape drive
subsystem, or hard-disk drive subsystem
Remote Configuration update
attempt failed
System was unable to process Remote
Configuration request.
Table 1-6. System Messages
System Message Corrective Action