Dell R900 Video Game Console User Manual


 
About Your System 29
E1811 HDD ## Rbld
Abrt
The specified hard drive
has experienced a rebuild
abort.
See "Troubleshooting a
Hard Drive" on page 142. If
the problem persists, see
your RAID
documentation.
E1812 HDD ##
Removed
The specified hard drive
has been removed from the
system.
Information only.
E1913 CPU &
Firmware
Mismatch
The BMC firmware does
not support the processor.
Update to the latest BMC
firmware. See the
BMC
User’s Guide
for more
information on setup and
use of BMC.
E1A14 SAS Cable A
SAS cable A is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Card" on page 78.
E1A15 SAS Cable B
SAS cable B is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Card" on page 78.
E2010 No Memory
No memory is installed in
the system.
Install memory. See
"General Memory Module
Installation Guidelines" on
page 92.
E2011 Mem Config
Error
Memory detected, but is
not configurable. Error
detected during memory
configuration.
See "Troubleshooting
System Memory" on
page 139.
E2012 Unusable
Memory
Memory is configured, but
not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 139.
E2013 Shadow BIOS
Fail
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 139.
Table 1-5. LCD Status Messages
Code Test Causes Corrective Actions