Dell R900 Video Game Console User Manual


 
32 About Your System
E2112 Mem Spare
Crd # DIMM
##
The system BIOS has
spared the memory
because it has determined
that the memory had too
many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If
no memory card is present,
the "Crd #" string is left
out of the message.
See "Troubleshooting
System Memory" on
page 139.
E2113 Mem Mirror
Crd # DIMM
## & ##
The system BIOS has
disabled memory mirroring
because it has determined
that one half of the mirror
has had too many errors.
"## & ##" represents the
DIMM pair implicated by
the BIOS. If no memory
card is present, the "Crd #"
string is left out of the
message.
See "Troubleshooting
System Memory" on
page 139.
E2118 Fatal NB
Mem CRC
One of the connections in
the Fully Buffered DIMM
(FBDIMM) memory
subsystem link on the
Northbound side has
failed.
See "Troubleshooting
System Memory" on
page 139.
E2119 Fatal SB
Mem CRC
One of the connections in
the FBDIMM memory
subsystem link on the
Southbound side has
failed.
See "Troubleshooting
System Memory" on
page 139.
I1910 Intrusion
System cover has been
removed.
Information only.
Table 1-5. LCD Status Messages
Code Test Causes Corrective Actions