Dell R900 Video Game Console User Manual


 
24 About Your System
E1210 CMOS Batt
CMOS battery is missing,
or the voltage is out of
acceptable range.
See "Troubleshooting the
System Battery" on
page 136.
E1211 ROMB Batt
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "Installing a
RAID Battery" on page 84,
and "Troubleshooting the
System Battery" on
page 136.
E1229 CPU # VCORE
Processor # VCORE
voltage regulator has failed.
See "Getting Help" on
page 165.
E1310 RPM Fan ##
RPM of specified cooling
fan is out of acceptable
operating range.
See "Troubleshooting
System Cooling" on
page 138.
E1313 Fan
Redundancy
The system is no longer
fan-redundant. Another
fan failure will put the
system at risk of
overheating.
Check control panel LCD
for additional scrolling
messages. See
"Troubleshooting System
Cooling" on page 138.
E1410 CPU # IERR
Specified microprocessor is
reporting an internal error.
See your system’s
Information Update Tech
Sheet located on
support.dell.com for the
most current system
information. If problem
persists, see "Getting Help"
on page 165.
Table 1-5. LCD Status Messages
Code Test Causes Corrective Actions