Block 8 - SpreadNet Programming
The SpreadNet Programming Block has a total of 45 Command Locations (CL 001 - 045). The SpreadNet transmitters
must be programmed with the SpreadNet Programmer. Refer to the Sierra Reference Manual for additional information.
SpreadNet Channel
Cmd Loc 001
Default 1
Range 1 - 2
Comments
Unique Property Code used to identify a transmitter as being part of the
system. Program one digit per Cmd Loc.
Comments
The Spread Spectrum channel used by the system.
SpreadNet Property Code
Cmd Loc 002 003 004 005
Default 0001
Range 0001 - 4048
SpreadNet Zone Transmitter Supervisory Rates
(Zones 1 - 32)
Cmd Loc 006 007 008 009 010 011 012 013
Zone # 1 2 3 4 5 6 7 8
Cmd Loc 014 015 016 017 018 019 020 021
Zone # 9 10 11 12 13 14 15 16
Cmd Loc 022 023 024 025 026 027 028 029
Zone # 17 18 19 20 21 22 23 24
Cmd Loc 030 031 032 033 034 035 036 037
Zone # 25 26 27 28 29 30 31 32
Default 1 (All CL)
Range 1 - 4 (All CL)
Comments
The Supervisory Rate is the time interval
between transmitter check-ins. A total of
eight consecutive supervisory check-ins
must be missed before a supervisory fail-
ure is reported.
SpreadNet Keypad Supervisory Rate
(Keypads 1 - 8)
Cmd Loc 038 039 040 041 042 043 044 045
Keypad # 1 2 345678
Default 1 (All CL)
Range 1 - 4 (All CL)
Block 9 - Partition (Area) Programming
This Block has 178 Command Locations (CL 001 - 178) and is used to define all partition information, including which
zones, user codes, and keypads are assigned to each partition. SpreadNet SN991-REMOTEs and SN961-KEYFOBs are
associated with a specific user number and both sections must be programmed for them to function.
Partition Type
Cmd Loc 001
Default 1
Range 1 - 3
Comments
This option is used to specify whether or
not a partitioned system has a common
area and the type of display used in the
common area.
Options:
1 Unsupervised, Battery
status sent hourly
2 30 seconds
3 120 seconds
4 300 seconds
If option 1 is selected, unsupervised transmitters will send battery status
hourly, only if they are within range of the receiver. Transmitters which are
out of range will not be reported as missing, because they are unsu-
pervised.
Options:
1 No Common Area
2 Common Area - Full
View Keypad
3 Common Area - Limited
View Keypad
Zone Assignments to Areas (Zones 1 - 32)
Cmd Loc 002 003 004 005 006 007 008 009
Zone # 1 2 3 4 5 6 7 8
Cmd Loc 010 011 012 013 014 015 016 017
Zone # 9 10 11 12 13 14 15 16
Cmd Loc 018 019 020 021 022 023 024 025
Zone # 17 18 19 20 21 22 23 24
Cmd Loc 026 027 028 029 030 031 032 033
Zone # 25 26 27 28 29 30 31 32
Default 1 (All CL)
Range 0 - 8 (All CL)
Comments
Each zone may be individually assigned to an
Area (Partition) or disabled.
Options:
0 Zone Disabled
1 Area 1
2 Area 2
3 Area 3
4 Area 4
5 Area 5
6 Area 6
7 Area 7
8 Area 8