Sierra S5832SG Video Game Controller User Manual


 
15
Options:
1 250 mS
2 500 mS
Comments
These Options select the zone response time (in mil-
liseconds) of zones 1 - 8 and zones available from
the S5058 Zone Expansion Module.
All zones on the S5058 ZEM use the same re-
sponse time.
Zone Response Time (Zones 1 - 8)
Cmd Loc 068 069 070 071 072 073 074 075
Zone # 1 2 3 4 5 6 7 8
Cmd Loc 076 (Zone Expander Module #1)
Zone # 9 thru 16
Cmd Loc 077 (Zone Expander Module #2)
Zone # 17 thru 24
Cmd Loc 078 (Zone Expander Module #3)
Zone # 25 thru 32
Default 2 (All CL)
Range 1 - 2 (All CL)
Options:
1 Keypad Buzzer
2 Pulsing Sounder (1.5s on/off)
3 Steady Sounder
4 Temporal Code 3 (0.5s on/
0.5s off 2x, 0.5s on/ 1.5s off)
5 On 1 Min./Off 30s
(repeated twice)
6 On 1 Min./Off 30s
(repeated 5x)
7 Silent
Comments
These options program the opera-
tion of the internal and external
sounders. Both internal and exter-
nal sounders will operate together.
Programming options 5 and 6 also
limit the duration of the sounder
outputs.
Exceptions are: Keyswitch/Spread-
Net Arming Annunciation (Block 3,
CL 051) and Ringback (Block 4,
CL 115).
Audible Cadence (Zones 1 - 32)
Cmd Loc 079 080 081 082 083 084 085 086
Zone # 1 2 3 4 5 6 7 8
Cmd Loc 087 088 089 090 091 092 093 094
Zone # 9 10 11 12 13 14 15 16
Cmd Loc 095 096 097 098 099 100 101 102
Zone # 17 18 19 20 21 22 23 24
Cmd Loc 103 104 105 106 107 108 109 110
Zone # 25 26 27 28 29 30 31 32
Default 3 (All CL)
Range 1 - 7 (All CL)
Options:
1 Normally Closed
2 Normally Open
3 EOL
4 Supervised EOL
5 Tamper (2 EOL)
6 SpreadNet RF
Comments
Tamper zones use 2 EOL resistors and may
detect 4 discreet conditions (normal, fault/
alarm, trouble, and tamper).
If any zone is designated as a SpreadNet
zone, it will automatically be ignored as a
hardwired zone.
Zone Circuit Type (Zones 1 - 32)
Cmd Loc 111 112 113 114 115 116 117 118
Zone # 1 2 3 4 5 6 7 8
Cmd Loc 119 120 121 122 123 124 125 126
Zone # 9 10 11 12 13 14 15 16
Cmd Loc 127 128 129 130 131 132 133 134
Zone # 17 18 19 20 21 22 23 24
Cmd Loc 135 136 137 138 139 140 141 142
Zone # 25 26 27 28 29 30 31 32
Default 3 (All CL)
Range 1 - 6 (All CL)
Options:
0 Disabled
1 Zone 1 9 17 25
2 Zone 2 10 18 26
4 Zone 3 11 19 27
8 Zone 4 12 20 28
16 Zone 5 13 21 29
32 Zone 6 14 22 30
64 Zone 7 15 23 31
128 Zone 8 16 24 32
Comments
If programmed for chime, these zones will
sound at the keypad when the control panel
is disarmed and the zone is faulted. It is used
for delay, interior, and instant zones only. The
program value is a total of all zones in the
group which will have Chime enabled.
Chime Enable
Zones: 1 - 8 9 - 16 17 - 24 25 - 32
Cmd Loc 143 144 145 146
Default 0 0 0 0
Range 0 - 255 0 - 255 0 - 255 0 - 255
Block 2 - Zone Configuration Programming (cont.)
For devices requiring 10K EOL resistor, use zone 7 and remove J5. Refer
to the S5090 Sierra Reference Manual for additional information.
Comments
These four command locations determine
which zones a user may manually bypass (if
authorized in Block 1, CL 021 - 080).
Zone bypass enable is divided into groups
of 8 zones each. The program value is a total
of all zones in the group which may be by-
passed.
Zone Bypass Enable
Zones: 1 - 8 9 - 16 17 - 24 25 - 32
Cmd Loc 147 148 149 150
Default 255 255 255 255
Range 0 - 255 0 - 255 0 - 255 0 - 255
Options:
0 Disabled
1 Zone 1 9 17 25
2 Zone 2 10 18 26
4 Zone 3 11 19 27
8 Zone 4 12 20 28
16 Zone 5 13 21 29
32 Zone 6 14 22 30
64 Zone 7 15 23 31
128 Zone 8 16 24 32