Sierra S5832SG Video Game Controller User Manual


 
19
Comments
If enabled, this option disables the strobe/siren, to extend
backup time with a low battery condition.
Strobe/Siren Disable with Low Battery
Cmd Loc 035
Default 2
Range 1 - 2
Comments
If enabled, alarm conditions programmed as silent will con-
vert to audible.
Phone Line Cut or Comm Fail Indication (Silent
to Audible)
Cmd Loc 036
Default 1
Range 1 - 2
Phone Line Cut Audible Action
Cmd Loc 037
Default 1
Range 1 - 3
Comments
Determines the audible action
to be taken when the tele-
phone line has been cut.
Options:
1 No Local Audible Annunciation.
2 Turn On Sounders.
3 Turn On Sounders only if armed.
Comments
Amount of time the internal siren and external bell will sound following an
alarm condition. Sounder cadence is progammed in Block 2, CL 079 - 110.
Internal/External Sounder Output Duration
(Minutes)
Cmd Loc 038
Default 5
Range 0 - 60
Comments
This option specifies the duration of the strobe
output (in days) following an alarm condition.
Strobe Output Duration (Days)
Cmd Loc 039
Default 7
Range 0 - 7
Comments
Panel will operate as a local system only during this period. This will give
the user time to learn the system. All alarm indications during this period will
only be annunciated by keypad buzzer. The internal and external sound-
ers are also disabled during this period.
Soak Mode (Learning Period) Duration (Days)
Cmd Loc 040
Default 0
Range 0 - 31
Comments
If enabled, the duress code will only disarm the system. The
duress code may not be used for arming.
Duress Active Only When (Area) Armed
Cmd Loc 041
Default 2
Range 1 - 2
Comments
An Opening Report will be sent if the following conditions
are met:
Opening Report Programming Override
Cmd Loc 042
Default 1
Range 1 - 2
Comments
Number of seconds that elapse following an alarm condition before the
internal siren/external bell sounds. The keypad buzzer is active during this
period.
Sounder Turn-On Delay Following Alarm (Seconds)
Cmd Loc 034
Default 0
Range 0 - 255
Block 3 - Armed System Programming (cont.)
Comments
If enabled, provides for supervision of external bell wiring
for opens, shorts, and ground faults. Bell supervision re-
quires an EOL resistor at the bell terminals. This option may
not be used if External Bell Reverse (Block 3, CL 048) is
External Bell Supervision Enable
Cmd Loc 043
Default 1
Range 1 - 2
Options:
1No
2Yes
Options:
1No
2Yes
Options:
1No
2Yes
1 - An alarm has occurred;
2 - the cancel report timer (Block 4, CL 110) has expired; and
3 - a valid user code is entered.
The report is sent, regardless of the User Code Privileges (Block 1,
CL 021 - 080) assigned to the user. The report will not override First
to Open/Last to Close (Block 9, CL 110) option.
Options:
1No
2Yes
If disabled, this option will send a duress report when arming or disarming.
Options:
1No
2Yes
active.
For proper supervision, Ground Fault Supervision (Block 3, CL 053) should
also be enabled.
Options:
0 Strobe Disabled
1 - 6 Days
7 Strobe Latched