Sierra S5832SG Video Game Controller User Manual


 
17
Comments
If enabled, the keypad buzzer sounds during the exit delay.
The keypad buzzer rate is faster during the last 10 seconds
of the exit delay.
Keypad Buzzer During Exit Delay
Cmd Loc 011
Default 2
Range 1 - 2
Comments
If enabled, the keypad buzzer sounds during the entry de-
lay. The keypad buzzer rate is faster during the last 10
seconds of the entry delay.
Keypad Buzzer During Entry Delay
Cmd Loc 012
Default 2
Range 1 - 2
Comments
This option controls the zone
and status displays of the
LED keypad.
NOTE: The Power and Arm
LEDs on all keypads oper-
ate the same.
Keypad LED Status
Cmd Loc 013
Default 1
Range 1 - 3
Options:
1 Always display arm and zone status
2 Status always on while disarmed. If
armed, status displayed for 30 secs.
3 Display arm and zone status for 30
seconds following User Code entry.
Comments
If programmed for cross-zoning, any two
of the zones listed here must be violated
while armed in order for an alarm condition
to register.
If the system is divided into areas, both
zones in alarm must be within the same area.
Cross-Zoning List
Zones: 1 - 8 9 - 16 17 - 24 25 - 32
Cmd Loc 014 015 016 017
Default 0 0 0 0
Range 0 - 255 0 - 255 0 - 255 0 - 255
Options:
0 Disabled
1 Zone 1 9 17 25
2 Zone 2 10 18 26
4 Zone 3 11 19 27
8 Zone 4 12 20 28
16 Zone 5 13 21 29
32 Zone 6 14 22 30
64 Zone 7 15 23 31
128 Zone 8 16 24 32
Comments
If enabled, quick bypass allows any user to bypass zones
without entering a user code. To bypass a zone, press the
[Bypass] key followed by the 2-digit code for the zone to be
bypassed.
Quick Bypass Enable
Cmd Loc 006
Default 1
Range 1 - 2
Comments
If enabled, the exit delay (Block 2, CL 003) will start when a
user presses and holds the [Home] key for two seconds. If
disabled, the exit delay will be ignored and the system will
home arm instantly.
Home Arm Exit Delay Enable
Cmd Loc 007
Default 1
Range 1 - 2
Comments
If enabled, the exit delay (Block 2, CL 003) will restart if the
delay zone is faulted a second or subsequent time during
the exit delay. The exit delay may be restarted up to 4 times.
4X Exit Delay Extension Enable
Cmd Loc 008
Default 2
Range 1 - 2
Comments
If enabled, all sounders (internal and external) will chirp for
three seconds at the start of the entry delay (Block 2, CL
001 or 002).
Chirp-Alert on Exit Fail
Cmd Loc 009
Default 2
Range 1 - 2
Comments
If enabled, allows the system to be armed even if the back-
up battery is low.
Low Battery Arming
Cmd Loc 010
Default 2
Range 1 - 2
Block 3 - Armed System Programming (cont.)
NOTE: Fire, delay, and keyswitch zones
are ignored if placed on the cross-zone list.
Options:
1No
2Yes
Options:
1No
2Yes
Options:
1No
2Yes
Options:
1No
2Yes
Options:
1No
2Yes
Options:
1No
2Yes
Options:
1No
2Yes
Comments
Zones listed here must be violated twice
(or any two zones must be faulted) within
a 30-second period in order for an alarm
condition to register.
If the system is divided into areas, the
alarms must be within the same area.
Double-Knock List
Zones: 1 - 8 9 - 16 17 - 24 25 - 32
Cmd Loc 018 019 020 021
Default 0 0 0 0
Range 0 - 255 0 - 255 0 - 255 0 - 255
Options:
0 Disabled
1 Zone 1 9 17 25
2 Zone 2 10 18 26
4 Zone 3 11 19 27
8 Zone 4 12 20 28
16 Zone 5 13 21 29
32 Zone 6 14 22 30
64 Zone 7 15 23 31
128 Zone 8 16 24 32
NOTE: Fire, delay, and keyswitch zones
are ignored if placed on this list.