Block 7 - Auxiliary Devices Programming
The Auxiliary Devices Programming Block has a total of 79 Command Locations (CL 001 - 079). Each of the first 11
commands has an input range of 1 - 82. Additional relay Options are provided for setting up specific timing operations.
On Board Relay
Cmd Loc 001
Default 1
Range 1 - 82
Relay #1 - REMM #1
Cmd Loc 002
Default 1
Range 1 - 82
Relay #2 - REMM #1
Cmd Loc 003
Default 1
Range 1 - 82
Relay #3 - REMM #1
Cmd Loc 004
Default 1
Range 1 - 82
Relay #4 - REMM #1
Cmd Loc 005
Default 1
Range 1 - 82
Relay #5 - REMM #1
Cmd Loc 006
Default 1
Range 1 - 82
Relay #1 - REMM #2
Cmd Loc 007
Default 1
Range 1 - 82
Relay #2 - REMM #2
Cmd Loc 008
Default 1
Range 1 - 82
Relay #3 - REMM #2
Cmd Loc 009
Default 1
Range 1 - 82
Relay #4 - REMM #2
Cmd Loc 010
Default 1
Range 1 - 82
Relay #5 - REMM #2
Cmd Loc 011
Default 1
Range 1 - 82
Options:
1 Disabled, relay open
2 Close on SN Door button (keypad or re-
mote) activation
3 Closed when entire system armed
4 Closed when entire system disarmed
5 0.5 sec on/off (3x) when keyswitch or Spread-
Net arming; 1.5 sec on for keyswitch or
SpreadNet disarming (ignores timer)
6 Close on any tamper
7 Close when phone line cut
8 Close when comm fail occurs
9 3-sec toggle to activate listen-in (ignores timer)
10 Follow keypad audible sounder (exit/entry de-
lays, area 1 only) (ignores timer)
11 Close on fault (except 24-hr. zone); open when
faulted zone is bypassed, restored, system
armed, or timer
12 Close on any alarm
13 Close on fire alarm
14 Close on burglar alarm
15 Close on panic/holdup
16 Close in installer programming mode
17 Activated by Commander II (RPS)
18 Close at end of exit delay (all areas armed),
open at start of entry delay
19 Close on area 1 alarm
20 Close on area 2 alarm
21 Close on area 3 alarm
22 Close on area 4 alarm
23 Close on area 5 alarm
24 Close on area 6 alarm
25 Close on area 7 alarm
26 Close on area 8 alarm
27 Close when area 1 armed
28 Close when area 2 armed
29 Close when area 3 armed
30 Close when area 4 armed
31 Close when area 5 armed
32 Close when area 6 armed
33 Close when area 7 armed
34 Close when area 8 armed
35 Close when armed, oscillate at 0.5 Hz when
home armed (area 1)
36 Close when armed, oscillate at 0.5 Hz when
home armed (area 2)
37 Close when armed, oscillate at 0.5 Hz when
home armed (area 3)
38 Close when armed, oscillate at 0.5 Hz when
home armed (area 4)
39 Close when armed, oscillate at 0.5 Hz when
home armed (area 5)
40 Close when armed, oscillate at 0.5 Hz when
home armed (area 6)
41 Close when armed, oscillate at 0.5 Hz when
home armed (area 7)
42 Close when armed, oscillate at 0.5 Hz when
home armed (area 8)
43 Close on relay user code 14 entry
44 Close on relay user code 18 entry
45 Close on relay user code 22 entry
46 Close on relay user code 26 entry
47 Close on relay user code 30 entry
48 Close on relay user code 34 entry
49 Close on relay user code 38 entry
50 Close on relay user code 42 entry
51 Close on user code entry (area 1)
52 Close on user code entry (area 2)
53 Close on user code entry (area 3)
54 Close on user code entry (area 4)
55 Close on user code entry (area 5)
56 Close on user code entry (area 6)
57 Close on user code entry (area 7)
58 Close on user code entry (area 8)
59 Close on duress (area 1), open on next area 1
user code entry (except Duress code)
60 Close on duress (area 2), open on next area 2
user code entry (except Duress code)
61 Close on duress (area 3), open on next area 3
user code entry (except Duress code)
62 Close on duress (area 4), open on next area 4
user code entry (except Duress code)
63 Close on duress (area 5), open on next area 5
user code entry (except Duress code)
64 Close on duress (area 6), open on next area 6
user code entry (except Duress code)
65 Close on duress (area 7), open on next area 7
user code entry (except Duress code)
66 Close on duress (area 8), open on next area 8
user code entry (except Duress code)
67 Relay status #1 (see below) (ignores timer)
68 Relay status #2 (see below) (ignores timer)
69 Close on bell supervision trouble
70 Close on keypad/accessory trouble or tamper
71 Close on Medical alarm
72 3-sec toggle for annunciator shutoff (ignores
timer)
73 3-sec toggle on local bell test (ignores timer)
74 Close on alarm associated with zone activated
relay (see Block 7, CL 035 - 066)
75 Close on AC fail
76 Close on low battery
77 Close on chime zone fault
78 Close on system trouble
79 Close on Pre-set Timer #1 (Block 7, CL 067 -
069)
80 Close on Pre-set Timer #2 (Block 7, CL 070 -
072)
81 Close on Pre-set Timer #3 (Block 7, CL 073 -
075)
82 Close on Pre-set Timer #4 (Block 7, CL 076 -
078)
Relay status #1 Relay status #2
System Status Alarms? Relay State System Status Alarms? Relay State
Disarmed No Closed Disarmed No Open
Disarmed Yes Open Disarmed Yes Open
Armed No Closed Armed No Closed
Armed Yes Open Armed Yes Open
NOTE: Relays are open when de-energized.
NOTE: All relays may be programmed to open ac-
cording to a timer (Block 7, CL 013 - 034), unless
otherwise indicated. For additional information,
refer to the S5090 Reference Manual.