Sierra S5832SG Video Game Controller User Manual


 
20
Comments
These locations are Reserved for Future Use and are not available in this
firmware version.
Comments
If enabled, supplies voltage to external bell when bell is off.
This option may not be used with External Bell Supervision
(Block 3, CL 043) enabled.
External Bell Reverse Enable
Cmd Loc 048
Default 1
Range 1 - 2
Sounder (Bell) Test Enable (By Area)
Cmd Loc 049
Default 0
Range 0 - 255
Comments
Sounds a 5-second bell test at the start of each exit
delay. The value programmed into this Cmd Loc is the
total of all areas for which the bell test will be active.
Options:
0 Disabled
1 Area 1
2 Area 2
4 Area 3
8 Area 4
16 Area 5
32 Area 6
64 Area 7
128 Area 8
Block 3 - Armed System Programming (cont.)
Options:
1No
2Yes
Home Arming Enable
Cmd Loc 050
Default 1
Range 1 - 2
Comments
This option, when enabled, allows a system to be home
armed or instant home-armed. All zones listed in the
Home Arm Bypass List (Block 2, CL 151 - 154) will be
automatically bypassed.
Options:
0 No Annunciation
1 Keypad Buzzer
2 Strobe
4 Internal Siren
8 External Bell
Keyswitch/SpreadNet Arming Annunciation
Cmd Loc 051
Default 0
Range 0 - 15
Reserved for Future Use
Cmd Loc 046 047
Default 0 0
Range N/A N/A
Options:
1No
2Yes
Comments
This option determines how keyswitch or
SpreadNet arming is annunciated. The value
programmed into this Cmd Loc is the total of
all sounders to be activated. When arming,
the selected sounders will beep three times
(1.5 sec on/off) and the strobe will light for 3
seconds. When disarming, the selected
sounders will beep once and the strobe will
be on for 1.5 seconds.
Options:
0 Disabled
1 Saturday
2 Friday
4 Thursday
8 Wednesday
16 Tuesday
32 Monday
64 Sunday
Auto-Arming Enable (Day of Week)
Cmd Loc 052
Default 0
Range 0 - 127
Comments
This will automatically arm the areas specified in
Block 3, CL 022 at the time specified in Block 3,
CL 023 and 024. The value programmed here is
the total for all days of the week when the system
will auto-arm.
Ground Fault Supervision Enable
Cmd Loc 053
Default 1
Range 1 - 2
Comments
This option, when enabled, reports and annunciates all
ground fault conditions.
When disabled, these conditions are not reported or
annunciated.
Options:
1No
2Yes
Comments
Each Cmd Loc will be programmed with
the total of the keypad addresses with ac-
tive tamper switches.
Keypad Tampers are reported via the
keypad bus.
Keypad Tamper Switch Enable (By Address)
Keypad # 1 - 8 9 - 16
Cmd Loc 044 045
Default 0 0
Range 0 - 255 0 - 255
Options:
0 Disabled
1 Keypad 1 9
2 Keypad 2 10
4 Keypad 3 11
8 Keypad 4 12
16 Keypad 5 13
32 Keypad 6 14
64 Keypad 7 15
128 Keypad 8 16