Sierra S5832SG Video Game Controller User Manual


 
14
Options:
0 Limited Functions**
1 Disarm
2 Arm
4 Bypass
8 Open/Close Rpt
16 Lang. Code opt. 1
32 Lang. Code opt. 2
Comments
These programming Options determine which
Options the user is authorized to perform.
Some user codes may have alternate func-
tions. (See Block 9 - Partition Programming
in the Sierra Reference Manual for additional
information.)
User Code Privileges (User # 1 - 60)
Cmd Loc 021 022 023 024 025 026 027 028
User # 1 2 3 4 5 6 7 8
Cmd Loc 029 030 031 032 033 034 035 036
User # 9 10 11 12 13 14 15 16
Cmd Loc 037 038 039 040 041 042 043 044
User # 17 18 19 20 21 22 23 24
Cmd Loc 045 046 047 048 049 050 051 052
User # 25 26 27 28 29 30 31 32
Cmd Loc 053 054 055 056 057 058 059 060
User # 33 34 35 36 37 38 39 40
Cmd Loc 061 062 063 064 065 066 067 068
User # 41 42 43 44 45 46 47 48
Cmd Loc 069 070 071 072 073 074 075 076
User # 49 50 51 52 53 54 55 56
Cmd Loc 077 078 079 080
User # 57 58 59 60
Default 15 (All CL)
Range 0 - 47 (All CL)
Block 2 - Zone Configuration Programming
Block 2 is divided into 160 Command Locations (CL 001 - 160) which are used to program the characteristics of each of the zones
in the control panel. The features include Delay Times, Zone Type, Zone Restoral Type, Zone Response Time, Audible Cadence,
Circuit Type, Chime Enable, Shunt Enable, and Home Arm Shunt List. The soft zone programming uses CL 155 - 160.
Entry Delay #1
Cmd Loc 001
Default 20
Range 10 - 255 (Seconds)
Comments
This establishes the first of two delay times for entry zones. Time is entered
in seconds.
Entry Delay #2
Cmd Loc 002
Default 40
Range 10 - 255 (Seconds)
Comments
This establishes the second of two delay times for entry zones. Time is
entered in seconds.
Exit Delay
Cmd Loc 003
Default 60
Range 20 - 255 (Seconds)
Comments
This establishes the delay time for exit zones. The time programmed into
this location should allow the user to use the exit farthest from the keypad.
Time is entered in seconds.
Options:
0 Disabled
1 Entry Delay 1/Exit
2 Entry Delay 2/Exit
3 Interior Instant
4 Interior Delay 2
5 Instant (Perim.)
6 Day Buzzer/Inst
7 Day Buzzer/Delay
Comments
These programming
Options determine the
zone type for each zone
(hardwired or wireless)
in the system.
Zone Type (Zones 1 - 32)
Cmd Loc 004 005 006 007 008 009 010 011
Zone # 1 2 3 4 5 6 7 8
Default 1 3 3 5 5 5 5 10
Cmd Loc 012 013 014 015 016 017 018 019
Zone # 9 10 11 12 13 14 15 16
Cmd Loc 020 021 022 023 024 025 026 027
Zone # 17 18 19 20 21 22 23 24
Cmd Loc 028 029 030 031 032 033 034 035
Zone # 25 26 27 28 29 30 31 32
Default 0 (CL 012 - 035)
Range 0 - 15 (All CL)
8 Day Bell/Inst
9 Day Bell/Delay
10 24-Hr. BA
11 Fire (FA)
12 Tamper
13 Panic/Hold-Up
14 Emergency-Med
15 Keyswitch **
Language Program Value
English 0
Spanish 16
Italian 32
Block 1 - Code Option Programming (cont.)
Option Set #2
1 Disabled
2 Arm/Disarm
3 Arm Only
4 Disarm Only
5 N/A
Comments
Option #1 values are
used for all zone types
except Keyswitch.
Keyswitch zones will
use the second set of
Options. Default value
for keyswitch is 2
(Arm/Disarm).
Zone Restoral Type (Zones 1 - 32)
Cmd Loc 036 037 038 039 040 041 042 043
Zone # 1 2 3 4 5 6 7 8
Cmd Loc 044 045 046 047 048 049 050 051
Zone # 9 10 11 12 13 14 15 16
Cmd Loc 052 053 054 055 056 057 058 059
Zone # 17 18 19 20 21 22 23 24
Cmd Loc 060 061 062 063 064 065 066 067
Zone # 25 26 27 28 29 30 31 32
Default 2 (All CL)
Range 1 - 5 (All CL)
Option Set #1
1 Disabled
2 Return to normal
3 Return to normal
and bell silenced
4 Return to normal
and not armed
5 User code entry
(zone may remain
faulted)
** If the Zone Type is programmed as Keyswitch, then Zone Restoral
Type (Block 2, CL 036 - 067) will be programmed using Option #2
values.
** Limited Functions are user number specific.
They may include relay operation, restricted
SN device operation, and some end-user
functions.