Installer Programming Report Routing
Cmd Loc 155
Default 2
Range 1 - 5
Comments
Report routing for installer programming start
and end reports (see Block 5, CL 135 - 138).
Bell Supervision Trouble Report Routing
Cmd Loc 156
Default 2
Range 1 - 5
Comments
Report routing for external bell supervision
trouble and restoral reports.
SpreadNet Transmitter Low Battery Report Routing
Cmd Loc 157
Default 2
Range 1 - 5
Comments
Report routing for all SpreadNet transmitters
low battery and restoral reports.
Block 4 - Digital Communicator Programming (cont.)
Keypad and Accessory Tamper Report Routing
Cmd Loc 158
Default 2
Range 1 - 5
Comments
Report routing for all tamper and restoral re-
ports associated with keypads and accesso-
ries connected to the system.
Duress Report Routing
Cmd Loc 149
Default 2
Range 1 - 5
Opening / Closing Report Routing
Cmd Loc 150
Default 2
Range 1 - 5
Test Report Routing
Cmd Loc 151
Default 2
Range 1 - 5
Comments
Report routing for all duress codes. Areas
are indicated by the account number.
Comments
Report routing for opening and closing re-
ports, if enabled.
Comments
Report routing for test reports.
Power Supply Report Routing
Cmd Loc 152
Default 2
Range 1 - 5
Phone Line Trouble Report Routing
Cmd Loc 153
Default 2
Range 1 - 5
Comments
Report routing for AC power fail, low battery,
and the respective restoral reports.
Comments
Report routing for phone line cut or comm fail
reports.
Kidwatch Check-In Fail Report Routing
Cmd Loc 154
Default 2
Range 1 - 5
Comments
If Kidwatch is enabled and the Kidwatch code
is not entered during the Kidwatch window
(Block 6, CL 006 - 009), a report will be sent.
Options:
1 Disable Reports
2 Receiver 1 Only
3 Receiver 2 Only
4 Receivers 1 and 2
5 Receiver 1, with
Receiver 2 as Back-
up, Alternating
Comments
These locations determine the report routing
for alarms, bypasses, troubles, tampers,
restorals, and cancel reports on all zones.
Report Routing (Zones 1 - 32)
Cmd Loc 116 117 118 119 120 121 122 123
Zone # 1 2 3 4 5 6 7 8
Cmd Loc 124 125 126 127 128 129 130 131
Zone # 9 10 11 12 13 14 15 16
Cmd Loc 132 133 134 135 136 137 138 139
Zone # 17 18 19 20 21 22 23 24
Cmd Loc 140 141 142 143 144 145 146 147
Zone # 25 26 27 28 29 30 31 32
Default 2 (All CL)
Range 1 - 5 (All CL)
Keypad Medical, Police, and Fire Report Routing
Cmd Loc 148
Default 2
Range 1 - 5
Comments
Report routing for soft zone alarms, if soft
zones are enabled (Block 2, CL 155 - 157).