Q-Logic 2400 Video Gaming Accessories User Manual


 
6–iSCSI Noninteractive Commands
-lcd (Display Configured Link Configuration)
SN0054667-00 C 6-15
-lcd
(Display Configured Link Configuration)
To display the configured link settings, issue the -lcd command. Note that because
a system reset is required for changes in link configuration to take effect, the
settings shown here may be different than the operating link configuration.
-linkchap
(Assign a CHAP Entry to a Target)
To link a CHAP entry to a target, issue the -linkchap command as follows:
–linkchap <hba port#> <chap#> <targetID> [<TGTBCA> <on|off>]
Where TGTBCA is an optional parameter to turn BIDI CHAP authentication on or
off for this target connection.
For example, to link a CHAP entry 9 on port 2 to target 10 with BIDI CHAP turned
on, issue the following command:
-linkchap 2 9 10 TGTBCA on
This command does not reset the adapter.
-lp
The IPv6 local prefix list is created based on prefix information from router
advertisements. Destination IP addresses containing these prefixes can be
reached directly, without going through an intermediate router.
To display the local prefix list, issue the -lp command as follows:
-lp <hba_port_inst>
-model
To view the adapter “model(s)” (board type[s]) in the system, issue the -model
command as follows:
-model
-n
(Configure iSCSI Settings)
To set to adapter iSCSI parameters for single-port adapters, issue the -n
command as follows:
-n <HBA No.> <Config Name|Config Alias> <Value>
[<Config Name|Config Alias> <Value> ]
After you issue this command, the adapter is reset.