Agilent Technologies 71501D Video Eyeware User Manual


 
2-21
Application Tutorials
Tutorial 6: Test to Industry Standards
Stop on and Display Trace Errors
The eye-diagram analyzer has the ability to stop data acquisition when a mask
violation occurs. The number of traces or errors that stop this data acquisition
can be specified. In addition, if you are in eyeline mode, you can separately
display the traces that have caused an error.
8 Set the bit interval and delay by pressing:
Setup, BIT INTVL and enter 1, DELAY and enter –3
The mask will be offset to the right side of the display.
9 Set the analyzer so testing will stop after two errors have occurred by pressing:
#Errors ON OFF ON
and enter 2
10 If #Traces is set to on, the eye-diagram analyzer stops sweeping when either
the error or trace limit is reached. Turn the number of traces function off by
pressing:
#Traces ON OFF OFF
11 Turn error tracing on by pressing:
err trc ON OFF ON
Any trace which violates the mask shows on the lower-half of the screen.
12 Reset and start the trace and error counters by pressing: