. S423 (CCU MODE SET 1)
Sets the CCU mode.
Factory setting : All OFF
-1 : Sets the SD signal format when S420 on the AT-149
board is set to position other than REMOTE.
ON : PAL (625/50)
OFF : NTSC (525/60)
-2 : The remote control code of MIC GAIN can be
switched to that of the HDCU-700A.
ON : HDCU-700A mode
OFF : Standard (default)
-3 : Selects the function of the MIC REMOTE connector
on the rear panel.
ON : WFM REMOTE CTL
OFF : MIC REMOTE CTL
-4 : Set the switch to OFF. (900)
-5 : Set the switch to OFF. (RCP-POW)
-6 :
The PIX select control from the RCP can be disabled.
ON : Enabled
OFF : Disabled
-7 : Set the switching control of PIX/WFM.
ON : Controllable only from RCP
OFF : Controllable from both MSU and RCP
-8 : Sets the reception mode of the camera HD-SDI
signal using the electrical coaxial cable. Set this
switch to OFF during ordinary operation.
ON : Depending on the setting of S414 on the AF-
149 board.
OFF : Connection by normal optical/electrical
composite cable
. S424-1 to 8
Factory use only
Factory setting : All OFF
. S427 (REFERENCE SIGNAL SEL)
Selects the type and phase control methods of the
external sync signal.
HD : Sync-locks to the HD reference signal.
(Supports automatically the frame frequency of
the reference signal to be input.)
BB : Sync-locks to the SD reference signal (BB).
(When the HKCU-951 is mounted, VBS OUT is
SC-locked.)
REM :Control is performed by RCP/MSU, etc.,
connected outside.
Factory setting : REM
. S428 (H PHASE COARSE)
Performs the fine adjustment of the H phase when S427 on
the AT-149 board is set to position other than REM. Perform
the coarse adjustment using S405 on the AT-149 board.
Factory setting : CENTER
OFF ON
1
2
3
4
5
6
7
8
First
digit
Second
digit
CCU No.
01
2
34
567
8
9
50 61 72 83 94
1-6. Setting of Switches on Boards
Factory setting : 60V (S418)
INTR (S419)
FORMAT S420 S418 S419
1080/60 (or 59.94) i 1.000 60V INTR
(or 1.001)
1080/30 (or 29.97) PsF 1.000 60V PROG
(or 1.001)
1080/50i 1.000 50V INTR
1080/25PsF 1.000 50V PROG
1080/24 (or 23.98) PsF 1.000 48V PROG
(or 1.001)
540/60 (or 59.94) PsF 1.000 60V 540P
(or 1.001)
n
540P and the formats other that what are describe above,
are not supported at present.
. S420 (FRAME FREQ.SELECT)
Select coefficient between x
1
and x
1
1.000 1.001
depending upon the HD signal frame frequency.
/1.001 :
1
times
1.001
/1.000 : 1 time
REMOTE : Control is performed by RCP/MSU, etc.,
connected outside.
Factory setting : REMOTE
. S421 (1-8 CCU No.)
This switch is mainly used to set the CCU numbers when
RCP is connected to the HDCU-950.
Use switches 1 to 8 to set the CCU numbers from 1 to 96
in BCD notation.
Use switches 1 to 4 to set the first digit and use switches
5 to 8 to set the second digit. (a to f are invalid.)
Factory setting : All OFF
. S422-1 to 5 (CCU MODE SET 2)
Sets the CCU mode.
Set all to OFF during ordinary operation.
Factory setting : All OFF
-6 : (RCP Sim-Cont)
-7 : (P-B CHARA MIX)
-8 : (TRUNK)