Multiple Address Monitoring
0000
0000
TIM 00
T00
0100
0000 T00
0100
0001 T00
0100
0001 T00
OFF 0100
D00 0001 T00
OFF 0100
D00 0001 T00
10FF OFF 0100
T00 D00 0001
0100 10FF OFF
D00 0001
10FF^ OFF
0001
OFF
0000
CONT 0001
0000
CHANNEL DM 00
Cancels monitoring of
leftmost address
Cancels Monitor
operation
7-3-2 Force Set/Reset
When the Bit/Digit Monitor operation is being performed and a bit, timer, or
counter address is leftmost on the display, PLAY/SET can be pressed to turn
ON the bit, start the timer, or increment the counter and REC/RESET can be
pressed to turn OFF the bit or reset the timer or counter. Timers will not oper-
ate in PROGRAM mode. SR bits cannot be turned ON and OFF with this op-
eration.
Bit status will remain ON or OFF for only one scan after pressing the key; it
will then return to its original status. When timers or counters are reset in
MONITOR mode, they will start after one scan.
This operation can be used in MONITOR mode to check wiring of outputs
from the PC prior to actual program execution. This operation cannot be
used in RUN mode.
Monitoring Operation and Modifying Data Section 7-3