Configuring the Network
Note: Include a trap IP address only if you have an SNMP trap receiver listening for this information.
HP proprietary SNMP trap events include fan failure, fan operational, and out-of-range
temperatures. General SNMP trap events include SNMP authentication failures, which are sent as
trap information.
You can download the HP ProCurve MIBs from the HP ProCurve support web site at
www.hp.com/go/hpprocurve.
Step 8. Type up to four Manager IP addresses in the fields provided.
These are the addresses of SNMP management consoles that are authorized to request
information.
You can enter the Manager IP address in any of the following forms:
• An IP addresses, such as 192.168.1.1
• An IP address with netmask, such as 192.168.1.0/24
• A hostname such as
snmp.fiesta.com
• A wildcard address, for example: 0.0.0.0/0.
Note: To query the SNMP agent from an SNMP console, you must include at least one Manager IP
address.
Step 9. Click Save to save your settings.
To restore the settings to the original default settings, click
Reset to Defaults.
To abandon your changes and revert to the current settings click
Cancel.
Setting the Date and Time
Accurate time and date reporting is necessary for logs and for troubleshooting. Accurate and
synchronized time and dates across multiple units is especially important. For example, if the date and
time of your Access Control Server and Access Controller are not synchronized, you may see negative
values for a client’s Idle Time in the Client Status display.
You use the Time and Date page to set the time zones and to set the date and time, either manually or
using a network time server. You can set the date and time separately for each system component, but
you should ensure that they are synchronized.
Note: You can change the time zone and set or modify the NTP server configuration in a single
operation, or you can change the time manually. However, once you make a change to either the time
zone or the NTP settings, you will not be able to change the date and time until you save (or cancel)
the time zone and NTP changes.
To configure the time and date for one or more components, do the following:
Step 1. Click the Date & Time tab from any page in the Network module.
The Date & Time page appears. See
Figure 6-20.
6-40 HP ProCurve Secure Access 700wl Series Management and Configuration Guide