Chapter 2: Installation
Installation Overview 2-1
Chapter 2
Installation
2.1. Installation Overview
CAUTION:
Please note that the installation instructions described in this manual should be
carefully followed. Failure do to so may result in damage to the system.
2.2. Installation Prerequisites
1. Static- free installation environment: The SR controller must be installed in a static
free environment to minimize the possibility of electrostatic discharge (ESD)
damage. (See Section 2.3.2).
2. Component check: Before the SR controller is installed, you should confirm that you
have received all the components on the Unpacking List during the unpacking
process. (See Section 2.5 )
3. Memory modules: Modules must be separately purchased and installed. (See Section
2.7)
4. Hard drives: SCSI-320 hard drives must be purchased separately prior to installation
of the SR controller.
5. Cabling: All the SCSI cables that are used to connect the SR controller to the host
and drives must be purchased separately. (See Section 4.2.1)
2.3. Safety Precautions
2.3.1 General Considerations
Power source: Make sure the power source is within the correct power range prior to
powering on.
Earth: Always make sure the controller has a safe electrical earth connection via the
power cords or chassis ground on the rack/cabinet.
Ventilation: Be sure that the rack cabinet provides sufficient ventilation channels
and airflow circulation throughout the enclosure in which the SR controller is
installed.