Sega 999-1108 Video Game Console User Manual


 
72
BASE SHAKER
does not react.
Operability of the
Steering wheel
(handle) is poor.
Steering wheel
(handle) is
abnormal in its
force feedback. It
is not centered.
Steering wheel
(handle) is week
in its force
feedback.
Shifter does not
operate normally.
Gas pedal
(accelletor) and/or
brake pedal do not
operate normally.
The Fluorescent
lamp does not
light up.
Lights integrated
with the start
button and the
view change
button do not
come on.
Failure of the
communication
play.
'ERROR *' is
displayed.
Incorrect volume adjustment.
Failure of the AMP or BASE
SHAKER
Deviation of the volume value.
Volume gear engagement fault.
Volume malfunctioning.
Failure of power-on checking
procedure.
The volume is not centered.
Failure of the volume.
Aging of the force feedback
mechanism.
Failure of the switch.
The volume is not centered.
Failure of the volume.
The Fluorescent tube is burnt out.
The lamp is burnt out.
Communication cables are
disconnected.
Communication cables are wrongly
connected.
Communication play is wrongly set.
Setting error in the test mode.
Adjust the SWITCH UNIT's volume.
(see 8-1)
Perform the OUTPUT TEST. (see 8-3)
Adjust the volume value in the Test mode.
(see 8-3)
Adjust the engagement of the gear.
(see 9-2)
Replace the Volume. (see 9-2)
Reconnect the power, and complete a
power-on checking procedure.
(see 5 Sec. 5,)
Adjust the volume value in the test mode.
(see Sec. 8)
Replace the volume. (see 9-1)
Reset in the test mode. (see Sec. 8)
Replace the switch. (see 10-2)
Adjust the volume value in the test mode.
(see Sec. 8)
Replace the volume. (see 11-1)
Replace the Fluorescent tube
(see Sec. 13).
Replace the lamp. (see Sec.13)
Reconnect the cables. (see 17-2)
Reconnect the cables correctly. (See 17-2)
Reset correctly. (see 17-3)
Reset correctly in the test mode according
to the product. (see Sec. 8)
TABLE 15 b
PROBLEMS CAUSE COUNTERMEASURES