Panasonic AW-RP120G Video Game Controller User Manual


 
34
<Operating procedure>
1. Connect the additional remote cameras and switcher
to be introduced and the unit to the network within the
same subnet.
2. Open AUTO IP menu [37], turn the F2 dial to display
“KEEP IP ADR” and press the F2 dial.
1.AUTO SET
KEEP IP ADR
Both the number of devices (all remote cameras and the switcher)
currently being managed by the unit and the number of new devices
detected are displayed on the LCD panel.
C:001/004 S:0/1
NO
C:001/004
Number of devices currently managed by the unit
+ number of new devices detected
Number of new devices detected
C: Remote camera, S: Switcher
3. Turn the F2 dial to select “Yes”, and then press the F2
dial.
Auto IP setting starts.
During auto IP setting, the progress is indicated by the number of
” which are reduced one by one.
1.AUTO SET
When all the operations have been completed successfully, the
following message appears.
1.AUTO SET
COMPLETE
The remote cameras can now be operated from the unit.
The function for linking the switcher with the unit can now be used.
When there is duplication between the IP addresses of the devices
in operation and the IP addresses of the additional remote cameras
to be introduced, the following message appears and the link
settings are not configured.
1.AUTO SET
IP Duplicate!
Check the IP addresses of the additional remote cameras to be
introduced, and then perform the auto IP setting operation again.
When setting the IP addresses failed, the following message
appears.
1.AUTO SET
SET UP ERR!
The cause of the problem is likely to be a network malfunction.
Check the connection status of the hub and LAN cables, and then
retry the auto IP setting operation.
Connection device detection
When the number of new devices detected by “RENEW IP ADR” or
“KEEP IP ADR” exceeds the number of devices that can be registered
(100 remote cameras and 1 switcher), “C/S OVER!” appears on the
bottom line of the LCD panel.
Auto IP setting can be executed even in this state, but IP addresses
will be set only for the number of devices that can be registered.
C:020/100 S:1/1
C/S OVER! YES
The unit may not be able to detect all of the remote cameras when,
for example, multiple remote cameras are started at the same time.
In such a case, select “RETRY” and then press the F2 dial to retry the
operation.
When the number displayed for the number of new devices detected
is lower than the actual number of devices to be set for reasons such
as some of the remote cameras or the switcher not being powered
on, resolve the problem and then select “RETRY” and press the F2
dial to execute the operation again.
C:020/020 S:1/1
RETRY
When adding another remote camera controller (AW-RP120 [this
unit] or AW-RP50), set an IP address that is not a duplicate of any
IP address within the same network before making the connection.
Execute auto IP setting when devices not applicable for auto IP
setting (devices other than the remote cameras and switcher) are
in a non-operation state. After executing auto IP setting, connect
these devices after checking that there is no duplicate IP address
within the same network.
Notes