Mitsubishi Electronics FX3U-CF-ADP Video Gaming Accessories User Manual


 
9 Program Examples
9.3 Program Example 2
92
FX3U-CF-ADP User's Manual
*1. When is "K7" or "K8", 00H, which indicates the end of the string, must be added to the end of
the character string. In addition, in sequence example, it is written in such a way that "00H" is placed
in a blank area of a character string. When a character string is modified, it is necessary ensure that
"00H" is placed at the end of the character string.
Time stamp setting.
D11K0
D12K1000
FNC 12
MOV
Data type setting.
Set the CF card use ratio.
A file is created.
Maximum line value setting.
M8405
CF card
is
mounted
M62 M8404
CF-ADP
unit ready
Remains ON
while a new
mixed type
file is being
created
FNC 12
MOV
D10K1
FNC 12
MOV
D13K80
FNC 12
MOV
K1D10D0
FNC305
FLCRT
K0
Remains ON while a new mixed
type file is being created.
D116D8418
D117D8417
FNC 12
MOV
The error code is stored.
Remains ON while a new mixed
type file is being created.
Remains ON while data names o
f
the mixed type are being written.
The error code details are
stored.
FNC 12
MOV
M63SET
M62RST
M62RST
M8029
M8329
D300"Bit"
FNC209
$MOV
M8405
CF card
is
mounted
M63 M8404
CF-ADP
unit ready
Remains ON
while data
names of the
mixed type
are being
written
Data name in the 1st column
D302"DEC 16bit"
FNC209
$MOV
Data name in the 2nd column
D307"DEC 32bit"
FNC209
$MOV
Data name in the 3rd column
D312"HEX 16bit"
FNC209
$MOV
Data name in the 4th column
D317
FNC209
$MOV
Data name in the 5th column
D322"Real number"
FNC209
$MOV
Data name in the 6th column
D328"Character string"
FNC209
$MOV
Data name in the 7th column
A mixed type file is created
Data names are written to the mixed type file.
"HEX 32bit"
To next pageTo next page
From previous pageFrom previous page
Execution
completion
Abnormal
end
*1
*1
*1
*1
*1
*1
*1
S2