Mitsubishi Electronics FX3U-CF-ADP Video Gaming Accessories User Manual


 
4 Installation
4.2 DIN rail mounting
24
FX3U-CF-ADP User's Manual
4.2 DIN rail mounting
The CF-ADP may be mounted on a 35mm (1.38") wide DIN46277 (DIN rail).
Connect the CF-ADP to the PLC main unit before attaching the CF-ADP to a DIN rail.
This section explains an example where the CF-ADP is connected to a FX
3U PLC. For the DIN rail mounting
method for other PLCs, refer to the respective PLC manual.
Refer to the FX
3U Hardware Edition
Refer to the FX
3UC Hardware Edition
1 Push out all DIN rail mounting hooks (A
in the figure on the right).
It is assumed that the CF-ADP has been connected
in advance. For the CF-ADP connection method,
refer to the following.
Refer to Section 4.1.
2 Fit the upper edge (B in the figure on the right) of the DIN
rail mounting groove onto the DIN rail.
3 Push the product onto the DIN rail.
4 Lock the DIN rail mounting hooks (A in the following figure) while pressing
the PLC against the DIN rail.