A SERVICE OF

logo

Changing the Default Keyboard Language (language)
Command
Example
The system displays a list of languages, each with a designated
number. To set the language environment variable to Svenska,
for example, you would enter 14 as shown in the example.
>>> set language
Return
0) Dansk 8) Francais (Suisse Romande)
1) Deutsch 9) Italiano
2) Deutsch (Schweiz) 10) Nederlands
3) English 11) Norsk
4) English (British/Irish) 12) Portugues
5) Espanol 13) Suomi
6) Francais 14) Svenska
7) Francais (Canadien) 15) Vlaams
3 >>>14
Return
LANGUAGE = 14
>>>
Changing the Default Fast SCSI (fast_scsi_a)(fast_scsi_b)
Description
The
fast_scsi_a
and
fast_scsi_b
environment variables
initialize the SCSI controllers. The variable
fast_scsi_a
is for
bus A (internal) devices, and
fast_scsi_b
is for bus B (external)
devices. When fast SCSI devices are connected and
fast_scsi_a
/b
is set to on, the SCSI firmware will operate in fast SCSI
mode. If both slow and fast SCSI devices are connected to the
same bus and the
fast_scsi_a/b
environment variable is on, the
firmware will differentiate between devices.
Note that the recommended maximum bus length is 4 meters
for slow SCSI devices and 3 meters for fast SCSI devices. When
these limits are exceeded, the SCSI bus is likely to have errors.
If your total bus length, including internal and external cables,
is greater than three meters, you must set the
fast_scsi_a/b
environment variable for that bus off.
Changing Environment Variables 10–11