MMB Web-UI (Web User Interface) Operations
OK
Warning
Displays the Voltage sensor type.
P1.8VL(*1)
P1.0VL(*1)
P2.5VL(*2)
P1.2VL(*2)
P0.8VL(*2)
P0.67VL(*2)
P3.3V(*3)
P1.8V_PCIEX#0(*1)
P1.8V_PCIEX#1(*1)
P1.8V(*2)
P0.9V_PCIEX#0(*3)
P0.9V_PCIEX#1(*3)
*1: IOUL,*2: IOUF,*3: IOUL/IOUF commonness
Displays the current power voltage.
Warning
(Low/High)
Lower and upper limits of the warning-level voltage.
Displays “ – ”, when the threshold is not set.
Displays the power voltage in the last two decimal places.
Critical
(Low/High)
Lower and upper limits of the critical-level voltage.
Displays “ – ”, when the threshold is not set.
Displays the power voltage in the last two decimal places.
TABLE 1.46 Button of [IOB#x] Screen
Turns on the Location LED by clicking [On] button.
Turns off the Location LED by clicking [Off] button
Clears the error status of IOU#x
When you click [Status Clear], the error message of the IOU gets cleared and it is possible to specify the
IOU at the time of next reboot. If error is detected again at the time of reboot, the error status of the IOU gets
registered once again.
(1) Menu Operation
[System] – [IOU] – [IOU#x]
(2) Window Operations
1. Click the [Status Clear] button.
Confirmation dialogue box is displayed.
2. Click the [Apply] button. Click the [OK] button to clear the error status and click the [Cancel] when you
do not want to clear the error status of the IOU.
[Message]
This section describes the messages to be displayed on this window.
Failed to clear the status.
For details on the messages displayed on the window, see PRIMEQUEST 2000 Series Message Reference
(C122-E178EN).