Western Telematic CMS-16 Video Game Console User Manual


 
[Enter]+++[Enter] Resident Disconnect Sequence
The Resident Disconnect Sequence is issued to disconnect your resident port from another port.
For example, if you are communicating via Port 3, and Port 3 is connected to Port 4, the
Resident Disconnect Sequence would be used to disconnect Port 3 from Port 4. Although the
default Resident Disconnect Sequence is [Enter]+++[Enter], the command format and Logoff
Character can also be redefined via the Port Configuration Menus as described in Section 5.5.3.
Note that a one character disconnect command can also be selected.
Availability: Supervisor / User
Format: [Enter]xxx[Enter]
Where "x" is the selected Logoff Character, and the default character is "+".
Response:
Verbose: The CMS will send the "Disconnected" message, followed by the Port Status
Screen.
Terse: 3
/C Connect
Establishes a bi-directional connection between two ports. For more information and command
line examples, please refer to Section 7.1. There are two different types of port connections:
Resident Connect: If the /C command specifies one port name or number, your resident
port will be connected to the specified port.
Third Party Connect: If the /C command specifies two port names or numbers, the unit
will connect the two ports indicated. A Third Party Connect command must be issued
from a third port with "Supervisor" command capability. "User" ports cannot initiate a
Third Party Connect.
Note:
Ports with "User" command capability can only connect to ports that share
the same Port Password.
Ports with "Supervisor" command capability are allowed to connect to all
other ports.
Availability: Supervisor / User
Format: /C <x> [x] [Enter]
Where x is the number or name of the port(s) to be connected.
Response:
WTI CMS-16; Console Management Switch -- User's Guide