Limit 5: Cable lengths
Refer to section 2.7:
With regenerative tap-offs, the maximum cable
length is 250 m from the central control unit to the
furthest device in any branch of the DCN.
The maximum cable length from the central control
unit to the first regenerative tap-off is 100 m.
The maximum length of the cable between
regenerative tap-offs is 100 m.
Open-ended cables can cause an incorrect operation
of the system.
2.5 Control capacity
2.5.1 Active devices
Active devices are devices that can:
Receive data from the central control unit.
Transmit data to the central control unit.
2.5.2 Passive devices
Passive devices can only receive data from the central
control unit.
2.5.3 Overview
The table shows the active and passive devices in the
DCN.
2.6 Power capacity
2.6.1 Introduction
Each device uses power and most devices do not have
an independent power supply.
2.6.2 Power consumption
The table shows the power each device in the DCN
uses.
Note
The total cable length includes the 2 m long
device cables.
Note
Active devices must have an address (refer to
section 12.2).
table 2.1: Active and passive devices
Device Type
DCN-DDB Passive/Active
DCN-DDI Active
DCN-FCS Passive
DCN-IDESK Active
table 2.2: Power consumption
Device Watt
DCN-DDB 2.0
DCN-DDI 4.5
DCN-FCS 0.9
DCN-IDESK 3.6