2.9 Interpretation devices
The maximum number of interpreter desks you can
install in an interpreter booth is six. Refer to figure 2.6
and figure 2.7 for two examples that use LBB4114/00
Trunk Splitters and LBB4115/00 Protected Trunk
Splitters.
With an LBB4114/00 Trunk Splitter, you can connect
the interpreter desks in series (refer to figure 2.6). If an
interpreter desk becomes defective, the defective desk
can have an effect on all other interpreter desks that
have a connection to the same trunk.
With an LBB4115/00 Protected Trunk Splitter, you can
connect two interpreter desks (refer to figure 2.7). If an
interpreter desk becomes defective, the defective desk
has no effect on all other interpreter desks that have a
connection to the same trunk.
figure 2.6: Interpreter booths with LBB4114/00
LBB4 11 4/00
figure 2.7: Interpreter booths with LBB4115/00
LBB4115/00
LBB4115/00
LBB4115/00