Bosch Appliances 9922 141 70691 en Video Gaming Accessories User Manual


 
Bosch Security Systems | 2007-02 | 9922 141 70691 en
DCN Wireless | Installation and User Instructions | Central Devices en | 47
You can select the procedure that is used to send audio
signals through the central control unit with the
available audio routing modes (refer to 10.6.8).
10.5.7 Fault contact
Use the fault contact to send the condition of the central
control unit to external devices. If the central control
unit operates correctly, the OK pins are internally
connected. The central control unit internally connects
the Fail pins when:
The central control unit is stopped.
The internal power supply unit operates incorrectly.
The central control unit does a reset.
table 10.16: Audio output details
Number of connections:
1x XLR plug for each audio output
1x double cinch socket for each audio output
Location:
Rear side
Cable:
Shielded cable
Maximum level:
Refer to appendix A
Nominal level (audio output 1):
Refer to appendix A
Nominal level (audio output 2):
Refer to appendix A
Frequency response:
-3 dB @ 30 Hz and 20 kHz
Impedance:
< 100
Signal-to-noise ratio:
> 89 dBA @ max. level
Crosstalk attenuation:
> 85 dB @ max. level
Distortion:
< 0.1% @ 100 Hz @ - 3 dB of the max. input
figure 10.10: Fault contact
table 10.17: Fault contact
Number of connections:
4-pole plug
Location:
Rear side
Signal:
Potential-free change-over relay
Voltage:
Max. 24 V(DC), 15 V(AC)
Current:
Max. 500 mA
OK Fail