Sega F355 Video Game Console User Manual


 
45 www.seuservice.com
FIG. 13 b
CRADLE
13. COIN SELECTOR
The coin selector should be cleaned once every
3 months. When cleaning, follow the procedure
below:
Turn the power for the machine OFF. Open the
coin chute door.
Open the gate and dust off by using a soft brush
(made of wool, etc.).
Remove and clean smears by using a soft cloth
dipped in water or diluted chemical detergent
and then squeezed dry.
Remove the CRADLE.
When removing the retaining ring
(E ring), be very careful so as not to bend the
rotary shaft.
Remove stain from the rotary shaft and shaft
receiving portions by wiping off with a soft
cloth, etc.
After wiping off as per above, further apply
a dry cloth, etc. to cause the coin selector to dry
completely.
CLEANING THE COIN SELECTOR
COIN INSERTION TEST
Once every month, when performing the Coin
SW Test, simultaneously check the following:
Does the Coin Meter count satisfactorily?
Does the coin drop into the Cashbox correctly?
Is the coin rejected when inserted while keeping
the Reject Button pressed down?
Remove and clean smears by using a
soft cloth dipped in water or diluted
chemical detergent and then
squeezed dry.
Never apply machine oil, etc. to the
Coin Selector.
After cleaning the Coin Selector,
insert a regular coin in the normal
working status and ensure that the
Selector correctly functions.
STOP
IMPORTANT!
FIG. 13 a
FIG. 13 c
GATE
Insert a coin
while keeping the
Reject Button
pressed down and
check if it is
rejected.
COIN METER
If the coin is not rejected when the REJECT button is pressed, open the coin chute door and
open the selector gate. After removing the jammed coin, put a normal coin in and check to see
that the selector correctly functions.
HANDLING THE COIN JAM
1
2
3
4
5
6
5