3Com 1500 Video Gaming Accessories User Manual


 
Configuring the PEM with the CLI 4-7
3
Set the ISDN switch type:
set imod int rm0/slot:1/mod:1 at at*w=[switch type]
4
Set the ISDN connection type:
set imod int rm0/slot:1/mod:1 at at*v2=5
set imod int rm0/slot:1/mod:2 at at*v2=5
You need to force a connection type for both channels (rm0/slot:1/mod:1
and rm0/slot:1/mod:2).
5
Save your changes:
set imod int rm0/slot:1/mod:1 at at&wz!
Configuring the
PEM with the CLI
The RAS 1500 stack does not immediately recognize the removal or
substitution of PEM units.
To remove and substitute another PEM module to an existing setup, issue
the
reboot
command at the CLI prompt.
After the reboot process occurs, RM automatically recognizes each PEM
attached to it.
See “Accessing the CLI Locally”, earlier in this chapter, to connect to the
Console Port.
Switch type Command
AT&T 5ESS
at*w=0
Northern Telecom DMS-100
at*w=1
National ISDN-1
at*w=2
ETSI
at*w=3
Germany
at*w=4
Australia
at*w=5
Italy
at*w=6
Japan
at*w=7
New Zealand
at*w=8
Spain
at*w=9
Taiwan
at*w=10