Polycom Version 2.0.3B Video Game Sound System User Manual


 
Technical Bulletin
SoundPoint
®
IP, SIP 2.1
3
Flash Parameter Configuration
The global
device
parameter has been modified to include the following:
Trademark Information
Polycom®, SoundPoint®, and the Polycom logo design are registered trademarks of Polycom, Inc. in the U.S. and
various countries. All other trademarks are the property of their respective companies.
Name Possible Values Description
device.syslog.serverName dotted-decimal IP address
OR
domain name string
The syslog server IP address or host name.
The default value is NULL.
device.syslog.transport None=0,
UDP=1,
TCP=2
The protocol that the phone will use to write to the
syslog server.
If set to “None”, transmission is turned off, but the
server address is preserved.
device.syslog.facility 0 to 23 A description of what generated the log message.
For more information, refer to section 4.1.1 of RFC
3165.
The default value is 16, which maps to “local 0”.
device.syslog.renderLevel 1 to 6 Specifies the lowest class of event that will be
rendered to syslog. It is based on
log.render.level
and can be a lower value.
Refer to Basic Logging <level/><change/> and
<render/> on page 138 of the SIP 2.0
Administrator’s Guide
.
device.syslog.prependMac Enabled, Disabled If enabled, the phone’s MAC address is prepended
to the log message sent to the syslog server.
Note
The parameters for this feature should be put in separate configuration files to
simplify maintenance. Do not add them to existing configuration files (such as
sip.cfg). Create a new configuration file for parameters that should apply to all
phones.
Polycom recommends that you test the new configuration files on two phones
before initializing all phones.