![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/9d/29df89b3-1283-4f0e-83d6-e23b8ba6645b/29df89b3-1283-4f0e-83d6-e23b8ba6645b-bg1c.png)
9.2 STORING DATA VIA RS232
To store data the commands are:
SUIDxxxxxx <CR> Store user ID data
SSIDxxxxxx <CR> Store scale ID data
SPLUxx,xxxxxxxxxxxx <CR> Store text data for PLUxx
When PLU text data is stored the Scale used, current unit weight and
current tare value is also stored to that PLU number.
For the SPLU command the data is: PLU number (2 characters), (Comma)
description (max 12 characters).
If the fields are less than the maximum all characters need not be used.
9.3 PLU ENTRY USING RS-232 INTERFACE
This will allow the scale data to be sent from a PC program as well as from
the keypad. The most common PLUs can be stored and recalled from the
scale memory. Other PLU data can be stored on a PC, then the text data,
unit weight and tare data can be sent from the PC to PLU00. This can then
be used and over written each operation.
OPERATION:
• Send tare data to set any tare value to be stored with PLU.
i.e. “T0.150” <CR>. If no tare is needed then you may send T0 to
delete any present tare data.
• Send the unit weight to be stored with PLU. ie. “U12.3456” <CR>
• Send PLU text data to be stored with current TARE and U/W values.
ie. “SPLU01,Parts” <CR>
© Adam Equipment Company 2007
27