Configuring the Switch
3-66
• Config Profile – In this version, only “DEFVAL” is displayed. In future versions,
a drop-down list of all configurable VDSL profiles will be displayed in this field.
• Alarm Config Profile – The alarm profile is pre-configured to send trap
messages via SNMP protocol to register errors on the VDSL line.
Web – Click VDSL, Line Configuration. Select the line from the drop-down list, and
click Query.
CLI – Use the show controllers efm line-table command.
Example
Displaying VDSL Interface Information
This Web screen displays physical interface information and channel interface
information for a selected VDSL line.
Command Attributes
• Line – Select the VDSL line from the drop-down list.
• Channel – Select Slow or Fast from the drop-down menu. The switch uses the
slow channel for data that requires a very low error rate in transmission. The
switch uses the fast channel for data such as voice/video signals that require
fast delivery, but for which a small error rate is acceptable.
• Side – This only displays Local. All information displayed is for data
transmission from the switch to the CPE.
Console#show controllers efm line-table 4-117
VDSL_LINE_ENTRY :
Ethernet 1/1 Line Coding 3
Ethernet 1/1 Line Type 4
Ethernet 1/1 Line Config Profile DEFVAL
Ethernet 1/1 Line Alarm Config Profile DEFVAL
.
.
.
VDSL_LINE_ENTRY :
Ethernet 1/12 Line Coding 3
Ethernet 1/12 Line Type 4
Ethernet 1/12 Line Config Profile DEFVAL
Ethernet 1/12 Line Alarm Config Profile DEFVAL
Console#