5.2.5 Programming a VectorScan, Continued
13. Press Enter ( ) when finished adding PreShots. The following commands are
displayed on the bottom of the monitor.
VectorScan Commands
E= Edit Press + or – key until E is displayed on LCD and press
Char Select. Reposition the PTZ and/or change the
lens settings, then repeat steps 6 and 7.
D = Delete Press + or – key until D is displayed on LCD and press
Char Select. The PreShot # entered in step 6 is
deleted.
S = Save Press + or – key until S is displayed on LCD and press
Char Select. The current PTZ and lens (focus and iris)
settings are saved for the PreShot # entered in step 6.
14. Press + or – until the character (E, D, or S) for the desired action is displayed on
the controller LCD and then press Character Select (
A
BC
).
15. Program another VectorScan or press Clear/Manual (
) to exit the PreShot
Programming menu.
5.2.6 Run VectorScan
To run a programmed VectorScan continuously:
1. Enter the VectorScan # (0-9) using the numeric keys.
2. Press the VectorScan (
) key.
The VectorScan runs continuously until the KD6/HD6 receives another command.
To run a programmed VectorScan one time through the programmed PreShots:
1. Press the Dome Menu (
1. ___
3. ___
) key.
2. Press + or – until VectorScan Menu is displayed and press Enter (
).
3. Press + or – until Run Once is displayed on the LCD and press Enter (
).
3. Enter the VectorScan # (0-9) using the numeric keys.
4. Press Enter (
).
The dome goes to each programmed PreShot at the velocity programmed and for the
dwell time specified and then stops.