Ruby Tech PM0426-13 Video Game Console User Manual


 
COPYRIGHT © 2005 MERIT INDUSTRIES, INC.
PM0426-13 MEGATOUCH EVO ION OWNER’S MANUAL 2
General Care and Maintenance
NOTE: THIS GAME MUST ONLY BE SER-
VICED BY QUALIFIED SERVICE PERSON-
NEL.
CAUTION: THERE ARE HIGH VOLTAGE
PARTS IN THIS GAME. BE CAREFUL
WHEN SERVICING THE INSIDE OF THE
GAME. THE GAME SHOULD ALWAYS BE
UNPLUGGED BEFORE SERVICING.
Touchscreen/Joystick Calibration
NOTE: If you are using MegaWeb™ or
connecting your game to TouchTunes®
product, you must enable high resolu-
tion calibration in order to properly
view Web pages or activate all of
TouchTunes features. All ION ma-
chines, except for the Classic, can sup-
port this high resolution mode. To en-
able high resolution:
1. Press the SETUP button located on the
control board inside the CPU section.
2. Touch the System Menu button on
the first screen that appears.
3. Touch the Options button on the Sys-
tem Menu Screen.
4. Scroll through the options until you see
Enable Hi Resolution and touch the
box next to this option so that a check
appears in the box.
5. A warning that it should not be enabled
on Classic games will appear. If you
have a Classic game, touch No to exit.
If you have any other type of cabinet,
touch Yes to continue.
6. The game will now have high resolu-
tion enabled. Touch the X button in the
upper corner of the screen to exit out
of setup. Then continue with the fol-
lowing screen calibration steps.
How To Calibrate:
Find the CALIBRATE button on the con-
trol board inside the CPU section, and
press it to enter screen calibration
mode.
Touch the center of the first cross that
appears. Once you release your fin-
ger, a second cross will appear.
NOTE: You must hold your finger on
the cross for approximately 2 seconds
for the calibration to be recognized.
Touch the center of the second cross
that appears on the screen.
Once the second cross is touched and
released, another cross will appear on
the screen. To test the calibration of
the screen, touch the cross with your
finger and slowly drag your finger
around the screen. The cross should
follow your movement.
Touch the EXIT button.
If you have high resolution enabled, the game
will prompt you to go through the same steps
again for high resolution mode.
The game will then prompt you to cali-
brate the joystick. Move the joystick as
far left as it will go, release the joy-
stick, and then press one of the but-
tons on the joystick.
NOTE: The joystick may not appear
the be functioning correctly during
calibration, but it is important that you
continue the calibration steps. After
calibration has been completed, it will
function properly.
Move the joystick as far right as it will
go, release the joystick, and then press
one of the joystick buttons.
Move the joystick as far up as it will go,
release the joystick, and then press one
of the joystick buttons.