SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14
SMARTBOX Installation
Enclosure Internal Wiring
NEC/CEC and UL require that no wires cross within the Junction Box. Punch outs
have been provided on the bottom of the Junction Box to meet this requirement.
Battery Setup
FIRE HAZARD
Batteriesmustbesetcorrectlytoavoidexplosionorre.
Failure to follow this warning may result in death, personal
injury or property damage.
Battery setup takes place during the commissioning process and can be accessed
inthemenuwheretheinstallermustconguretheSMARTBOX™ Controller based
on what batteries are connected to the system. The following table shows the battery
options and the values that will be set up by default.
Theinstallerdoeshavetheoptiontocongurethechargingmanually.Ofthe
parameterslistedbelow,theinstallersetsuptherstthree:BatteryType,Battery
Banks and Capacity.
Battery Setup Chart
Setting Values Defaults Description
Battery Type Flooded
GEL
AGM
Flooded Sets the battery type and automati-
cally set the default values below
based on that type
Battery Banks 1-6 1 Sets the number of 24V paralleled
battery banks connected
Capacity 50-500 100 Ah Sets the amp-hour rating of ONE
battery
Recharge Voltage 20.0-27.0 V 22 V Sets the voltage at which the
charger transitions from absorption
to bulk charge
Figure 2.13 Battery Setup Chart
Connecting the SMARTBOX™ Controller
SHOCK HAZARD
Whenever a turbine is not locked and turning, a shock
hazard exists at the output wires or exposed terminals. To
reduce the risk of shock during installation, stop and lock
the turbine before making the connections. Failure to follow
this warning may result in death, personal injury or property
damage.
SHOCK HAZARD
Do not connect the battery negative to ground. Bonding
the battery negative to ground disables turbine ground-
fault protection. Failure to follow this warning may result in
death, personal injury or property damage.